The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (2 findings)
Item 08
Where it was found: Potable Water-Backflow Prevention - Cross-Connection Control Log
Official finding: Six non-testable backflow prevention devices for the newly added Deck 16 Crown Lounge did not have results recorded in the log. Crew provided the inspector with records from the ship's management system database which indicated these devices were inspected on 02 November 2025.
Official recommendation
Ensure the cross-connection control program includes at a minimum, a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location.
Item 08
Where it was found: Potable Water-Bunkering Residual Halogen and pH Log
Official finding: Two bunkering sessions at the Port of Miami recorded halogen residual and pH levels beyond the initial 30 minutes of the start of bunkering on the log. Below are the two bunkering sessions:
27 April 2026
Start time: 0750; First reading: 0842
20 April 2026
Start time: 0744; First reading: 0815
Official recommendation
Adjust the free halogen residual level to at least 2.0 mg/L (ppm) and the pH not to exceed 7.8 within 30 minutes of the start of the bunkering and production processes.
Galleys and dining rooms (26 findings)
Item 39
Where it was found: Buffet-Deck 15 - Windjammer Beverage Station Forward Port Side
Official finding: Flies were in the following food areas:
Deck 15
Windjammer
One fly was in the starboard forward buffet area.
Deck 15
Windjammer
One fly was in the starboard forward bakery area.
Deck 17
Coastal Kitchen
One fly was in the portside beverage station.
Deck 5
Main Galley Pantry
One fly was near the undercounter glasswashing machine.
Deck 4
Main Galley Beverage Station Starboard Side
One fly was in the area.
Deck 2
Vegetable Preparation
One fly was in the area.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 22
Where it was found: Galley-Deck 5 - Main Galley Dishwash
Official finding: Water leaked from the steam line at the bottom left of the wash compartment of the flight-type glasswashing machine. The water went into the scupper drain below. This was corrected before the end of the inspection.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction.
Item 08
Where it was found: Galley-Deck 5 - Main Galley Dishwash
Official finding: Water dripped consistently from the backflow prevention device on the middle spray arm of the drop-off area. This was corrected before the end of the inspection.
Official recommendation
Maintain backflow prevention devices in good repair.
Item 24
Where it was found: Galley-Deck 5 - Main Galley Potwash
Official finding: The manifold temperature of the hood-type potwash machine measured 196°F on the display screen gauge. The machine was immediately taken out of service, and the temperature was adjusted. The three-compartment sink was in active use.
Official recommendation
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines.
Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item 33
Where it was found: Galley-Deck 3 - Main Galley Pastry Walk-In Freezer
Official finding: Ice was inside the deckhead light fixture in the middle of the room. The deckhead light was cleaned immediately.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 33
Where it was found: Provisions-Deck 1 - General Frozen
Official finding: Ice was inside the deckhead light fixture in the middle of the room. The deckhead light was cleaned immediately.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 31
Where it was found: Buffet-Deck 15 - Windjammer Port Station
Official finding: A crew member was actively spraying insecticide along the deck outside of this outlet. The outlet was closed, however, all crew, food items, serving utensils and other food equipment had yet to be removed for discard or dishwashing.
Official recommendation
Ensure poisonous or toxic materials are used according to: (1) Law and VSP Environmental Public Health Standards; (2) Manufacturer's use directions included in labeling and, for a pesticide, manufacturer's label instructions stating that use is allowed in a food area; (3) Conditions of certification, if certification is required, for use of the pest-control materials.
Item 21
Where it was found: Galley-Deck 15 - Mason Jar
Official finding: The plastic handle of a soiled deep fat fry basket at the soiled staging area was broken in many places and difficult to clean. Black greasy food debris of more than a day's accumulation was in the difficult to clean areas.
Official recommendation
Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.
Item 27
Where it was found: Galley-Deck 15 - Mason Jar
Official finding: The plastic handle of a soiled deep fat fry basket at the soiled staging area had black greasy food debris of more than a day's accumulation in the difficult to clean areas.
Official recommendation
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item 21
Where it was found: Galley-Deck 15 - Mason Jar
Official finding: Excessive and peeling silicone was on the left side of the upper technical compartment metal housing of the combination oven.
Official recommendation
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item 28
Where it was found: Galley-Deck 15 - Port Bar Pantry
Official finding: Standing water was inside the bulk milk container of the previously cleaned and sanitized counter-mounted espresso machine. The unit was not in operation.
Official recommendation
Store clean equipment and utensils: (1) In a self-draining position that allows air drying; (2) Covered or inverted.
Item 21
Where it was found: Buffet-Deck 16 - El Loco
Official finding: Two fasteners were missing from the top of the grease chute housing. These fasteners were replaced.
Official recommendation
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item 21
Where it was found: Buffet-Deck 16 - El Loco
Official finding: The back right leg of the counter-mounted deli oven was not flush with the countertop exposing an open seam. Old food debris was in this opening.
Official recommendation
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item 27
Where it was found: Buffet-Deck 16 - El Loco
Official finding: An open seam between the back right leg of the counter-mounted deli oven and the countertop was soiled with old food debris.
Official recommendation
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item 26
Where it was found: Galley-Deck 16 - Solarium Bistro
Official finding: Red food debris was on the food-contact surface of a white serving platter set out on the preparation counter adjacent the large garbage receptacle where crew members were changing their gloves between task. Additionally, the serving platter was in direct contact with a closed hotel tray of raw beef burgers. The serving platter was sent to be cleaned and sanitized.
Official recommendation
Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item 28
Where it was found: Galley-Deck 16 - Solarium Bistro
Official finding: Red food splash was on the food contact surface of a white serving platter set out on the preparation counter adjacent the large garbage receptacle.
Official recommendation
Store cleaned equipment and utensils, laundered linens, and single-service articles and single-use articles: (1) In a clean, dry location; (2) In a location where they are not exposed to splash, dust, or other contamination; (3) At least 150 millimeters (6 inches) above the deck unless in packages on pallets, skids, or racks, which may be 127 millimeters (5 inches) above the deck.
Item 37
Where it was found: Galley-Deck 16 - Solarium Bistro
Official finding: Smoke and cooking vapors from the grill where burgers were cooking were not fully removed by the exhaust system. Smoke billowed outside the hood and clouded the adjacent working area.
Official recommendation
Ensure all food preparation, warewashing areas, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item 27
Where it was found: Buffet-Deck 15 - Windjammer Beverage Station Forward Port Side
Official finding: Standing water and debris were in the technical space under the ice dispensing machine.
Official recommendation
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item 36
Where it was found: Buffet-Deck 15 - Windjammer Juice Stations Forward Port and Starboard Side
Official finding: The light intensity did not reach 220 lux at the dispensing nozzles of the juice machines.
Official recommendation
Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces.
Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item 19
Where it was found: Buffet-Deck 15 - Windjammer Fruit Station Forward Port Side
Official finding: The tray of pineapple out for passenger self-service was missing tongs.
Official recommendation
Provide a food-dispensing utensil for each container of food displayed at a consumer self-service unit such as a buffet or salad bar.
Item 19
Where it was found: Buffet-Deck 15 - Windjammer Market Carvery Buffet Forward Port Side
Official finding: One tray of applesauce was unprotected. It was not entirely beneath the sneeze guard.
Official recommendation
Protect food from contamination by storing the food: (1) Covered or otherwise protected.
Item 28
Where it was found: Buffet-Deck 15 - Windjammer Buffet Forward Starboard Side
Official finding: The previously cleaned and sanitized spoon utensil holder had food debris inside of it.
Official recommendation
Store cleaned equipment and utensils, laundered linens, and single-service articles and single-use articles: (1) In a clean, dry location; (2) In a location where they are not exposed to splash, dust, or other contamination.
Item 21
Where it was found: Food Service General-Buffet Stations
Official finding: Open seams were around the hot and cold tops throughout the majority of the service lines. Additionally, several working sides of the countertops were in disrepair with cracks and gouges that were difficult to clean and maintain.
Official recommendation
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item 27
Where it was found: Food Service General-Buffet Stations
Official finding: More than a day's accumulation of food residue was in the cracks and seams around hot and cold tops throughout the majority of the service lines.
Official recommendation
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item 19
Where it was found: Buffet-Deck 15 - Windjammer Bakery Station Starboard Forward
Official finding: Bread rolls at the bakery station were not protected by the sneeze guard.
Official recommendation
Protect food on display from contamination by using packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (39 inches).
Item 26
Where it was found: Buffet-Deck 15 - Mason Jar Galley Pantry
Official finding: Food debris was in the difficult to clean areas of the previously cleaned and sanitized countertop mixer head.
Official recommendation
Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Heating, ventilation, and air conditioning (1 finding)
Item 43
Where it was found: Ventilation-Deck 2 - Fire Zone 5 Port side AC Room 52
Official finding: The HVAC unit supplying the crew cabins had black residue on the condensate collection panel.
Official recommendation
Inspect evaporative condensers at least annually and clean as necessary to remove scale and sediment. Clean cooling coils and condensate pans as necessary to remove dirt and organic material.
Other inspection items (3 findings)
Item 08
Where it was found: Pantry-Deck 6 - Schooner Bar
Official finding: The atmospheric vents of the backflow prevention device for the utility sink's pre-rinse spray arm were blocked with a white plastic material. Corrective actions started immediately.
Official recommendation
Maintain backflow prevention devices in good repair.
Item 33
Where it was found: Bar-Deck 15 - Mason Jar
Official finding: The bottle storage shelving where open liquor bottles were stored did not have coving along the sides and back of the elevated storage shelves.
Official recommendation
Cove all bulkhead/deck, equipment/deck, cabinet/deck, counter/bulkhead/backsplash, and deck sink coaming/deck junctures in galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, scrapping stations, food storage rooms, food transportation corridors, equipment or utensil storage rooms, and toilet rooms intended for use by food employees.
Item 26
Where it was found: Bar-Deck 15 - Mason Jar
Official finding: The previously cleaned and sanitized soda gun nozzle cap had an accumulation of dried food debris.
Official recommendation
Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Swimming pools and whirlpools (1 finding)
Item 10
Where it was found: Recreational Water Facilities-Main Pools - Life Saving Equipment
Official finding: The two flotation devices designated for both main pools (starboard and port side) did not have an attached rope that is at least two-thirds of the maximum pool width.
Official recommendation
Provide a rescue or an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3.3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency. Ensure the approved flotation device includes an attached rope that is at least two-thirds of the maximum pool width.
Gastrointestinal outbreak notices
No official CDC outbreak notice in the listings we collected is clearly matched to this ship. That is not a guarantee that no illness occurred; it only means none of the posted notices we have were matched here. See the outbreak list.
Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.