The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (4 findings)
Item 26
Where it was found: Potable Water-Engine Control Room Coffee Station
Official finding: Old coffee residue of more than a day's accumulation was on the underside dispensing nozzle housing and nozzle of the counter-mounted coffee machine.
Official recommendation
Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils. Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item 08
Where it was found: Potable Water-Hose and Fitting Storage Starboard
Official finding: Four fitting caps used for the 'potable water only' hoses were not stored in a sanitary manner.
Official recommendation
Handle and store all hoses, fittings, water filters, buckets, equipment, and tools used for connection with the bunkering of potable water in a sanitary manner.
Item 06
Where it was found: Potable Water-Legionella Sampling
Official finding: Legionella sampling is conducted onboard, however, areas such as galleys and water heaters were missing.
Official recommendation
Sample the potable water system for Legionella at least every 6 months. The Legionella sampling plan must include a selection of the following locations: (1) Potable water storage tanks; (2) Water heaters and hot water storage; (3) Hot water return lines; (4) Representative points of use in cabins, galleys, and recreational areas. Include a mix of fixture types (showers, sink faucets, tubs). Include potable water samples when temperatures are in the range favorable for Legionella growth (77°–113°F, 25°–45°C); (5) Decorative water features; (6) Misting systems; (7) Salon and pedicure devices; (8) Technical water sources with a risk of exposure via aerosolization to crew or passengers, such as deck washing.
Item 08
Where it was found: Potable Water-Engine Room Evaporator 1
Official finding: The technical water line from the evaporator 1 was striped blue/green/blue prior to the halogen injection point. This was removed and replaced immediately.
Official recommendation
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue).
Galleys and dining rooms (13 findings)
Item 33
Where it was found: Galley-Deck 9 - Aft Crew Elevator Food Transportation
Official finding: The deck tiles were chipped and in disrepair.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 33
Where it was found: Buffet-Deck 9 - Hot Line Portside
Official finding: An open gap was on the deckhead above the sneeze guards.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 39
Where it was found: Food Service General-Flies
Official finding: Flies were seen in the following areas:
Deck 7
Neptune Lounge
One small fly was in the pantry by ice machine.
Deck 3
Main Galley
One small fly was near the combination ovens.
Deck 2
Billboards Bar
One small fly was near the undercounter dishwash machine.
Deck 2
Main Galley Biodigestor
One fly was in the area.
Deck A
Officer Mess
One small fly was in the area.
Deck A
Crew Galley Potwash
One small fly was in the area.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 33
Where it was found: Preparation Room-Deck B - Freezer Room #1
Official finding: Ice build up was on the deckhead light fixture.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 36
Where it was found: Buffet-Deck 9 - Omelet Station Aft Portside
Official finding: The protective coating on the lights was peeling above the portable hot plates.
Official recommendation
Ensure light bulbs are shielded, coated, or otherwise shatter resistant in areas with exposed food; clean equipment, utensils, and linens; or unwrapped single-service articles and single-use articles.
Protect an infrared or other heat lamp against breakage by a shield surrounding and extending beyond the bulb so only the face of the bulb is exposed.
Item 33
Where it was found: Buffet-Deck 9 - Omelet Station Aft Starboard Side
Official finding: The deckhead light fixtures above the sneeze guards were not flush which caused an open gap.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 36
Where it was found: Buffet-Deck 9 - Aft Beverage Station
Official finding: The light intensity at the counter-mounted ice/water dispenser was less than 220 lux.
Official recommendation
Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces.
Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item 33
Where it was found: Galley-Deck 9 - Italian Station Pantry
Official finding: The potable water lines to the drinking fountain and handwashing station were not flush to the bulkhead creating an open penetration.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 33
Where it was found: Galley-Deck 3 - Cold Room #29
Official finding: Black residue was on the deckhead hatch near the condenser. The area was cleaned immediately.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 26
Where it was found: Galley-Deck 2 - Beverage Station Portside
Official finding: Two previously cleaned coffee dispensers had old milk residue on the dispensing nozzles.
Official recommendation
Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils. Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item 22
Where it was found: Galley-Deck 2 - Dishwash Station
Official finding: Water was leaking from underneath the wash tank compartment of the flight-type dishwash machine.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction.
Item 33
Where it was found: Galley-Deck 2 - Dishwash Station
Official finding: Water pooled on the deck from the wash tank of the flight-type dishwash machine .
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 08
Where it was found: Preparation Room-Deck A - Lido Preparation
Official finding: The backflow prevention device, at the wash sink, was consistently dipping water.
Official recommendation
Maintain backflow prevention devices in good repair.
Medical center (1 finding)
Item 02
Where it was found: Medical-Acute Gastroenteritis Log (AGE)
Official finding: The Excel version of the AGE surveillance log did not include a comments/notes column as specified in the VSP 2025 Environmental Public Health Standards.
Official recommendation
Complete all fields of the AGE surveillance log, even if entry is zero or nonapplicable. If a field is not completed, document the reason in the notes column (for example, a virtual consultation).
Ensure the log data is exported in an analyzable form (such as Microsoft Excel or Microsoft Access) in the exact order noted above. Ensure any additional data fields in the surveillance log are entered only outside of the form margins when exported.
Other inspection items (2 findings)
Item 33
Where it was found: Bar-Deck 9 - Sea View
Official finding: An open gap was between the bulkhead backsplash countertop juncture.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 36
Where it was found: Bar-Deck 2 - Gallery
Official finding: The light intensity was less than 110 lux at the crew handwashing station.
Official recommendation
Ensure the light intensity is at least 110 lux (10 foot-candles) at 750 millimeters (30 inches) above the deck in walk-in refrigerator units, dry storage areas, linen storage, waiter stations, scrapping stations, and handwashing stations in bars.
Swimming pools and whirlpools (1 finding)
Item 10
Where it was found: Recreational Water Facilities-Pools
Official finding: The depth markers for both pools were formatted in small font that are not easily read.
Official recommendation
Ensure depth markers are easily readable within the entire perimeter of the recreational water facility.
Gastrointestinal outbreak notices
These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.
Official outbreak notices collected for this ship
Swipe sideways to see every column.
Sailing dates
Causative agent
Case counts
Source
11/3/2016-11/18/2016
Norovirus
Passengers: 90 of 1,843 (4.88%). Crew: 22 of 796 (2.76%).