The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (1 finding)
Item 08
Where it was found: Potable Water-Engine Room
Official finding: The bunker/production potable water line was not striped blue/green/blue or blue after the chemical injection point.
Official recommendation
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue).
Galleys and dining rooms (6 findings)
Item 39
Where it was found: Buffet-Deck 12 Terrace Cafe
Official finding: Three flies were near the back counter on the cold cuts line. No food was impacted.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 19
Where it was found: Galley-Deck 12 Terrace Cafe
Official finding: Two bins of cut lettuce were unprotected in the time control refrigeration unit.
Official recommendation
Protect food from contamination by storing the food: (1) Covered or otherwise protected.
Item 22
Where it was found: Galley-Deck 12 Terrace Cafe
Official finding: The flight-type dishwash machine was out of order and under maintenance.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item 20
Where it was found: Food Service General-
Official finding: The following equipment in food areas was out of order and in need of maintenance:
Deck 12 Waves Galley: The far-left ice machine.
Deck 12 Aquamar Bar: The undercounter refrigerator.
Deck 5 Main Galley: The drawer refridgerator in the hot galley.
Deck 5 Main Galley: The upright refridgerator in the pantry area.
Official recommendation
Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards; (2) Can opener parts that cut or pierce must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
Item 24
Where it was found: Galley-Deck 5 Flight -Type Dishwash
Official finding: The temperature display gauge read 198°F for the final rinse manifold temperatures. Plate surface temperatures were measured within the appropriate range.
Official recommendation
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines.
Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item 19
Where it was found: Provisions-I-95 Corridor
Official finding: A pallet of potatoes was placed directly underneath the insect light trap. Crew stated active provisioning was being conducted during the inspection.
Official recommendation
Protect food from contamination that may result from a physical, chemical, biological origin. Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; (6) At least 150 millimeters (6 inches) above the deck on shelving units.
Medical center (1 finding)
Item 11
Where it was found: Medical-Reporting of Acute Gastroenteritis (AGE)
Official finding: On 17 March 2026 at 2330 a nonfood worker began experiencing symptoms of AGE. However, the individual did not report to medical until 18 March at 0500.
Official recommendation
When nonfood employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document the date and time of last symptom and clearance to return to work.
Other inspection items (2 findings)
Item 39
Where it was found: Bar-Deck 15 Horizons
Official finding: One fly was seen in the area.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 29
Where it was found: Other-Incinerator Room
Official finding: A large knife was stored on top of the handwashing sink.
Official recommendation
Ensure handwashing facilities are used for no other purpose and are always accessible.
Swimming pools and whirlpools (1 finding)
Item 10
Where it was found: Recreational Water Facilities-Deck 12 Main Pool
Official finding: The main pool's analyzer was not properly calibrated. The following free halogen residual measurements tested with the crew's kit from different locations in the pool were: 1.15ppm, 1.16ppm, 1.19ppm, and 1.41ppm . The inspector's reading was 1.21ppm. The analyzer's set point was 3.0. The inspector and technician then visited the equipment room, where the analyzer for the main pool read 3.63ppm. During manual sampling in the equipment room, the technician measured the free halogen residual at 2.05ppm and inspector measured 2.17ppm.
Official recommendation
Maintain and operate the halogen and pH analyzer-chart recorder in accordance with the manufacturer’s instructions. Conduct a manual comparison test before opening the RWF to verify calibration for free halogen residual and pH. Ensure the analyzer reading is within 0.2 mg/L (ppm) for free halogen and 0.2 for pH. For RWFs open longer than 24 hours, conduct a manual comparison test every 24 hours. Maintain and operate the halogen and pH analyzer-chart recorder in accordance with the manufacturer’s instructions. Conduct a manual comparison test before opening the RWF to verify calibration for free halogen residual and pH. Ensure the analyzer reading is within 0.2 mg/L (ppm) for free halogen and 0.2 for pH. For RWFs open longer than 24 hours, conduct a manual comparison test every 24 hours.
Gastrointestinal outbreak notices
These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.
Official outbreak notices collected for this ship
Swipe sideways to see every column.
Sailing dates
Causative agent
Case counts
Source
3/18/2019-4/5/2019
Unknown
Passengers: 36 of 1,066 (3.38%). Crew: 4 of 763 (0.52%).