The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (1 finding)
Item 06
Where it was found: Potable Water-Legionella Sampling Plan
Official finding: The Legionella sampling records provided did not identify the water heater and/or hot water storage were sampled within the previous six months as per the VSP 2025 Environmental Public Health Standards.
Official recommendation
Sample the potable water system for Legionella at least every 6 months. Ensure sample sites are representative of the potable water and RWF systems and number of samples depends on the size and complexity of the vessel.
Take follow-up actions when Legionella is detected based on the type of Legionella found, the concentration (for example in CFU/ml), and the extent of colonization. Actions can include (1) Review of the water management program; (2) Root cause analysis to understand possible reasons for Legionella growth; (3) Updates to the water management program if needed. Consider retesting fixtures or devices where Legionella was detected to confirm the effectiveness of the response and to determine if remediation is needed. For additional guidance, see ASHRAE Guideline 12, Appendix C5.
The Legionella sampling plan must include a selection of the following locations: (1) Potable water storage tanks; (2) Water heaters and hot water storage; (3) Hot water return lines; (4) Representative points of use in cabins, galleys, and recreational areas. Include a mix of fixture types (showers, sink faucets, tubs). Include potable water samples when temperatures are in the range favorable for Legionella growth (77°–113°F, 25°–45°C); (5) Decorative water features; (6) Misting systems; (7) Salon and pedicure devices; (8) Technical water sources with a risk of exposure via aerosolization to crew or passengers, such as deck washing.
Galleys and dining rooms (10 findings)
Item 36
Where it was found: Galley-Deck 2 - Warewash - Aft
Official finding: The light intensity was less than 220 lux on the soiled side of the flight-type dish wash machine.
Official recommendation
Ensure the light intensity is at least 220 lux on food preparation surfaces.
Ensure the light intensity is at least 220 lux as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item 39
Where it was found: Galley-Deck 2 - Beverage Station - Aft
Official finding: One fruit fly was in this area.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 19
Where it was found: Galley-Deck 2 - Dry Storage - Aft
Official finding: A container of salt did not have an identifying label. The salt was immediately discarded.
Official recommendation
Ensure containers holding food or food ingredients removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
Item 34
Where it was found: Galley-Deck 2 - Hot Galley
Official finding: Two sink faucets leaked and dripped water into stainless steel serving pans intended for ready-to-eat-food. No food was impacted.
Official recommendation
Ensure the plumbing system in food areas is in good repair.
Item 33
Where it was found: Galley-Deck A - Hot
Official finding: Water dripped and pooled on the deck from the far-right bains-marie technical space.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 39
Where it was found: Galley-Deck A - Beverage Station
Official finding: One fruit fly was in this area.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 27
Where it was found: Buffet-Deck 9 - Lido Market - Asian Station - Portside
Official finding: The bread toaster vent had an accumulation of dust. This was immediately corrected.
Official recommendation
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item 27
Where it was found: Buffet-Deck 9 - Lido Market - Italian Station
Official finding: The bread toaster vent had an accumulation of dust. This was immediately corrected.
Official recommendation
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item 36
Where it was found: Galley-Deck 9 - Dive In
Official finding: The light intensity was less than 220 lux at the grill near the entrance.
Official recommendation
Ensure the light intensity is at least 220 lux on food preparation surfaces.
Ensure the light intensity is at least 220 lux as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item 33
Where it was found: Galley-Deck 10 - Tamarind
Official finding: The deck grouting was in disrepair near the flat top grill.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Other inspection items (2 findings)
Item 20
Where it was found: Bar-Deck 2 - Ocean
Official finding: One soda gun had a slotted fastener in the food splash zone. This was corrected immediately.
Official recommendation
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; (5) Accessible for cleaning and inspection by one of the following methods: without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel.
Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item 20
Where it was found: Bar-Deck 2 - Piano
Official finding: One soda gun had a slotted fastener in the food splash zone. This was corrected immediately.
Official recommendation
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; (5) Accessible for cleaning and inspection by one of the following methods: without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel.
Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Gastrointestinal outbreak notices
These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.
Official outbreak notices collected for this ship
Swipe sideways to see every column.
Sailing dates
Causative agent
Case counts
Source
2/17-3/24, 2024
Norovirus
Passengers: 104 of 2,522 (4.12%). Crew: 17 of 961 (1.77%).