Jewel of the Seas

Royal Caribbean International · CDC Vessel Sanitation Program record

Satisfactory: score 99 out of 100

Latest inspection June 5, 2026 · CDC inspection report

CDC’s passing mark is 86 out of 100.

Cruise line
Royal Caribbean International
Inspections in this snapshot
38
Currently on the Green Sheet
Yes

Score history

Dates and scores are as CDC's inspection search returned them. Failing scores are shaded. Each report link goes to the official CDC page.

Score history for Jewel of the Seas

Inspection dateScore and official resultCDC report
June 5, 202699 SatisfactoryOfficial report
January 17, 202699 SatisfactoryOfficial report
September 12, 2025100 SatisfactoryOfficial report
April 29, 202597 SatisfactoryOfficial report
September 28, 2024100 SatisfactoryOfficial report
April 5, 202497 SatisfactoryOfficial report
September 14, 2023100 SatisfactoryOfficial report
November 19, 202297 SatisfactoryOfficial report
March 29, 201998 SatisfactoryOfficial report
December 29, 201896 SatisfactoryOfficial report
May 6, 201896 SatisfactoryOfficial report
January 7, 201895 SatisfactoryOfficial report
April 16, 201795 SatisfactoryOfficial report
November 18, 201697 SatisfactoryOfficial report
March 28, 201697 SatisfactoryOfficial report
November 23, 201595 SatisfactoryOfficial report
June 8, 201596 SatisfactoryOfficial report
January 24, 201599 SatisfactoryOfficial report
June 29, 2014100 SatisfactoryOfficial report
November 16, 201397 SatisfactoryOfficial report
April 4, 201399 SatisfactoryOfficial report
January 24, 201388 SatisfactoryOfficial report
September 23, 2012100 SatisfactoryOfficial report
April 23, 2012100 SatisfactoryOfficial report
September 25, 201194 SatisfactoryOfficial report
October 11, 2010100 SatisfactoryOfficial report
May 14, 2010100 SatisfactoryOfficial report
October 22, 2009100 SatisfactoryOfficial report
March 2, 200998 SatisfactoryOfficial report
October 31, 200898 SatisfactoryOfficial report
March 10, 200897 SatisfactoryOfficial report
November 20, 200799 SatisfactoryOfficial report
January 13, 200793 SatisfactoryOfficial report
September 23, 2006100 SatisfactoryOfficial report
March 25, 2006100 SatisfactoryOfficial report
September 22, 2005100 SatisfactoryOfficial report
February 14, 200599 SatisfactoryOfficial report
September 29, 2004100 SatisfactoryOfficial report

Latest official findings

The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.

Drinking water (1 finding)

Item 06

Where it was found: Potable Water-Legionella Testing

Official finding: The most recent Legionella sampling in January 2026 did not include representative points from the galleys. All other required sampling locations were included.

Official recommendation

Sample the potable water system for Legionella at least every 6 months. Ensure sample sites are representative of the potable water and RWF systems and number of samples depends on the size and complexity of the vessel. Take follow-up actions when Legionella is detected based on the type of Legionella found, the concentration (for example in CFU/ml), and the extent of colonization. Actions can include (1) Review of the water management program; (2) Root cause analysis to understand possible reasons for Legionella growth; (3) Updates to the water management program if needed. Consider retesting fixtures or devices where Legionella was detected to confirm the effectiveness of the response and to determine if remediation is needed. For additional guidance, see ASHRAE Guideline 12, Appendix C5. The Legionella sampling plan must include a selection of the following locations: (1) Potable water storage tanks; (2) Water heaters and hot water storage; (3) Hot water return lines; (4) Representative points of use in cabins, galleys, and recreational areas. Include a mix of fixture types (showers, sink faucets, tubs). Include potable water samples when temperatures are in the range favorable for Legionella growth (77°–113°F, 25°–45°C); (5) Decorative water features; (6) Misting systems; (7) Salon and pedicure devices; (8) Technical water sources with a risk of exposure via aerosolization to crew or passengers, such as deck washing.

Galleys and dining rooms (16 findings)

Item 22

Where it was found: Buffet-Deck 11 - Windjammer - Warewashing

Official finding: Four baskets of silverware closely clumped together that had been previously cleaned and sanitized through the flight-type warewashing machine were soiled with food debris. Corrective actions began immediately.

Official recommendation

Ensure soiled items to be cleaned in a warewashing machine are loaded into racks, trays, or baskets or onto conveyors in a position that (1) Exposes the items to the unobstructed spray from all cycles; (2) Allows the items to drain.

Item 26

Where it was found: Buffet-Deck 11 - Windjammer - Warewashing

Official finding: The following previously cleaned and sanitized utensils stored within four baskets of silverware on the clean landing of the hood type warewashing machine were soiled with food debris: - three forks - eleven spoons - one knife Corrective actions began immediately.

Official recommendation

Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.

Item 22

Where it was found: Buffet-Deck 11 - Windjammer - Warewashing

Official finding: Two final sanitizing rinse spray arm nozzles inside of the rack-type warewashing machine did not have a fan-like spray pattern. Corrective action began immediately.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction.

Item 33

Where it was found: Buffet-Deck 11 - Windjammer

Official finding: Water pooled inside four deckhead light fixtures in the walk-in refrigerator by the production area. This was corrected immediately.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 33

Where it was found: Buffet-Deck 11 - Windjammer

Official finding: Water pooled inside one deckhead light fixture in the walk-in refrigerator by the pantry. This was corrected immediately.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 33

Where it was found: Buffet-Deck 11 - Windjammer - Starboard Side Show Galley

Official finding: The white deckhead ventilation cover located above the serving line was peeling throughout. The venue was not in operation at the time of inspection.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.

Item 33

Where it was found: Buffet-Deck 11 - Windjammer - Starboard Side Show Galley

Official finding: Sealant along the left bulkhead on the employee side of the serving line was in disrepair exposing an open seam. This was corrected immediately.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.

Item 21

Where it was found: Buffet-Deck 11 - Windjammer - Starboard & Port Side Beverage Station

Official finding: The countertop junctures had open seams, adjacent to the trays of coffee mugs on the serving line. This was corrected immediately.

Official recommendation

Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Item 33

Where it was found: Buffet-Deck 11 - Windjammer - Middle Starboard Side Waiter Station

Official finding: The waiter station had three damaged deck tiles.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.

Item 33

Where it was found: Buffet-Deck 11 - Windjammer - Middle Port Side Waiter Station

Official finding: The waiter station had one damaged deck tile.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.

Item 17

Where it was found: Galley-Deck 11 - Solarium Cafe

Official finding: The cold well did not have a time control label as per the time control plan. The venue was in operation at the time of the inspection. This was corrected immediately.

Official recommendation

Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.

Item 22

Where it was found: Galley-Deck 5 - Potwash

Official finding: The hood-type warewashing machine had been out of order since 04 June 2026. Crew were aware and awaiting repair parts.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction.

Item 29

Where it was found: Galley-Deck 5 - Pastry

Official finding: The handwashing station was obstructed by a trolley cart. The venue was in operation at the time of the inspection with a food employee actively performing food preparation within the proximity of the handwashing station. This was corrected immediately.

Official recommendation

Ensure handwashing facilities are used for no other purpose and are always accessible.

Item 33

Where it was found: Galley-Deck 4 - Hot Production Area

Official finding: The following areas had cracked deck tiles and recessed grout:

  • Roast cook station around the flat-top grill
  • Underneath combination oven #47102
  • Underneath combination oven #47103
Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.

Item 24

Where it was found: Galley-Deck 4 - Warewashing

Official finding: The final sanitizing rinse plate surface temperature of the flight type warewashing machine was unable to achieve the required 160°F and above when tested using the crew and inspector's temperature measuring device. The following plate surface temperatures were recorded by the crew's tip sensitive thermometer: 156°F, 154°F, & 153°F. The inspector's temperature measuring device recorded a plate surface temperature of 158°F. The manifold reading was 176°F, which did not meet the minimum requirement of 180°F as per the data plate posted on the machine. Crew began immediate corrective actions and were finally able to achieve a plate surface temperature of 163°F. Food equipment was actively being washed and sanitized prior to arriving in this area. Crew returned all previously cleaned and sanitized food equipment to be reprocessed.

Official recommendation

In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.

Item 26

Where it was found: Galley-Deck 3 - Crew Mess

Official finding: The ice machine's evaporator deflector panel was soiled with a pink residue on the food-contact surface. Corrective action began immediately.

Official recommendation

Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils. Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.

Heating, ventilation, and air conditioning (1 finding)

Item 43

Where it was found: Ventilation-Decks 10 and 11 - Droplet Separators

Official finding: The droplet separators on the following air handling units were soiled with a significant amount of white and brown residue: Deck 10

  • Unit supplying the Bridge Deck 11
  • Unit supplying Windjammer Cafe
Official recommendation

Keep air handling units clean.

Other inspection items (3 findings)

Item 26

Where it was found: Bar-Deck 13 - Vortex Bar

Official finding: One beer dispensing nozzle was soiled on the interior surface with a brown residue. The venue was not in operation at the time of the inspection. Corrective action was initiated immediately.

Official recommendation

Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.

Item 33

Where it was found: Bar-Deck 11 - Solarium Bar

Official finding: Four open bottle shelves along the back bar counter were not coved.

Official recommendation

Cove all bulkhead/deck, equipment/deck, cabinet/deck, counter/bulkhead/backsplash, and deck sink coaming/deck junctures in galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, scrapping stations, food storage rooms, food transportation corridors, equipment or utensil storage rooms, and toilet rooms intended for use by food employees.

Item 17

Where it was found: Bar-Deck 3 - Crew Bar

Official finding: The counter-mounted milk storage unit for the coffee machine was not physically labeled as a time control equipment as per the time control plan. Corrective action began immediately.

Official recommendation

Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.

Pest and insect management (1 finding)

Item 39

Where it was found: Buffet-Integrated Pest Management - Flies

Official finding: The following food areas had flies:

  • Deck 11
  • Windjammer
  • Starboard Side Freestyle Beverage Station
  • Three small flies were between the bulkheads and the freestyle beverage machines.
  • Deck 11
  • Windjammer
  • Starboard Side Waiter Station
  • Three small flies were over the trash chutes.
  • Deck 11
  • Pool Bar
  • One fly was over the bar counter. The venue was in operation at the time of the inspection.
  • Deck 13
  • Vortex Bar
  • One fly was over the bar counter. The venue was not in operation at the time of the inspection.
Official recommendation

Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.

Gastrointestinal outbreak notices

These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.

Official outbreak notices collected for this ship

Sailing datesCausative agentCase countsSource
1/28-2/3, 2023NorovirusPassengers: 68 of 2,185 (3.11%). Crew: 1 of 865 (0.12%).CDC notice
02/22/2010-03/05/2010UnknownPassengers: 102 of 2,158 (4.7%). Crew: 14 of 848 (1.6%).CDC notice

Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.