Ilma

Ritz-Carlton Yacht Collection · CDC Vessel Sanitation Program record

Satisfactory: score 94 out of 100

Latest inspection March 31, 2026 · CDC inspection report

CDC’s passing mark is 86 out of 100.

Cruise line
Ritz-Carlton Yacht Collection
Inspections in this snapshot
3
Currently on the Green Sheet
Yes

Score history

Dates and scores are as CDC's inspection search returned them. Failing scores are shaded. Each report link goes to the official CDC page.

Score history for Ilma

Inspection dateScore and official resultCDC report
March 31, 202694 SatisfactoryOfficial report
November 7, 202593 SatisfactoryOfficial report
February 8, 202593 SatisfactoryOfficial report

Latest official findings

The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.

Drinking water (4 findings)

Item 06

Where it was found: Potable Water-Legionella Sampling

Official finding: No samples were collected from the hot water heater (or proxy location) or salon pedicure basin within the past six months. (VSP 2025 Environmental Public Health Standards)

Official recommendation

Sample the potable water system for Legionella at least every 6 months. Ensure sample sites are representative of the potable water and RWF systems and number of samples depends on the size and complexity of the vessel. The Legionella sampling plan must include a selection of the following locations: (2) Water heaters and hot water storage; (7) Salon and pedicure devices.

Item 08

Where it was found: Potable Water-Deck 1 - Starboard Bunkering Station

Official finding: The potable water bunkering hose stored on the top shelf inside the locker was constructed of woven material that is difficult to clean. The upper edge of the hose was frayed, creating multiple difficult-to-clean surfaces. Crew initiated corrective action.

Official recommendation

Construct all hoses, fittings, and water filters used in the bunkering of potable water of safe, easy-to-clean materials approved for potable water use and maintain them in good repair.

Item 08

Where it was found: Potable Water-Deck TT - Production Room

Official finding: A hose was connected to the potable water cold supply hose bib without appropriate backflow prevention. Crew initiated corrective action.

Official recommendation

Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (7) Hose-bib connections.

Item 08

Where it was found: Potable Water-Deck TT

Official finding: The external sampling cock for potable water tank PW 212 was in disrepair and not turned downward. Crew initiated corrective action.

Official recommendation

Ensure sample cocks are pointed down, identified, and numbered with the appropriate tank number.

Galleys and dining rooms (17 findings)

Item 22

Where it was found: Dining Room-Deck 5 - Beach House

Official finding: Clean utensils, soiled equipment, and packaged food items were commingled on top of numerous waiter stations in the bar and the show galley. No designated clean and soiled areas were identified on these counters. Crew initiated corrective action.

Official recommendation

Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for utensil holding before cleaning and after sanitizing.

Item 19

Where it was found: Galley-Deck 5 - Beach House - Show Galley

Official finding: Numerous food items were offered for passenger self-service on a buffet without sneeze guards or other protection from contamination. Crew initiated corrective action.

Official recommendation

Protect food on display from contamination by using packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (39 inches).

Item 28

Where it was found: Dining Room-Deck 5 - Beach House

Official finding: Clean utensils, soiled equipment, and packaged food items were commingled on top of numerous waiter stations in the bar and the show galley. No designated clean and soiled areas were identified on these counters. Crew initiated corrective action.

Official recommendation

Store cleaned equipment and utensils, laundered linens, and single-service articles and single-use articles: (1) In a clean, dry location; (2) In a location where they are not exposed to splash, dust, or other contamination.

Item 19

Where it was found: Dining Room-Deck 5 - Beach House

Official finding: Packaged food items were commingled with clean utensils and soiled equipment on top of numerous waiter stations in the bar and the show galley. No designated clean and soiled areas were identified on these counters. Crew initiated corrective action.

Official recommendation

Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination. Protect food from contamination that may result from a physical, chemical, biological origin.

Item 33

Where it was found: Dining Room-Deck 10 - Mistral

Official finding: The deckhead above two waiter stations and the food staging areas was perforated, exposing the plenum above. Crew provided a purchase order for the replacement deckhead.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure slots for supply ventilation over the void space (plenum) are not directly over food preparation areas, food storage areas, or clean equipment storage. This applies to vessels built or renovated in accordance with the 2011 VSP Construction Guidelines or later. Ensure bulkheads and deckheads have smooth, hard finishes.

Item 19

Where it was found: Dining Room-Deck 10 - Mistral

Official finding: The deckhead above two waiter stations and the food staging areas was perforated, exposing the plenum above. Food items were temporarily stored at the portside staging area. Crew provided a purchase order for the replacement deckhead.

Official recommendation

Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination. Do not store foods: (10) In areas not finished in accordance with 7.6.5 and 7.6.6 for food storage areas.

Item 20

Where it was found: Galley-Deck 10 - Mistral

Official finding: One previously cleaned and sanitized cutting board was heavily scored, creating numerous difficult-to-clean surfaces. This cutting board was stored on a clean storage rack.

Official recommendation

Materials used in the construction of multiuse utensils and food-contact surfaces of equipment must be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices.

Item 27

Where it was found: Galley-Deck 10 - Mistral

Official finding: Paper product labels were affixed to the exterior surfaces of previously cleaned and sanitized water carafes, creating difficult-to-clean surfaces. Crew initiated corrective action.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 24

Where it was found: Galley-Deck 10 - Mistral Warewashing Area

Official finding: The sanitizing solution in the three-compartment sink measured less than 50 mg/L (ppm). The sink was in active use with multiple pieces of equipment and utensils washed in this ineffective sanitizing solution.

Official recommendation

Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).

Item 34

Where it was found: Galley-Deck 10 - Mistral Hot Area Preparation Area

Official finding: Plastic food service gloves were secured to potable water lines to stop two leaks in the technical area below the countertop heating units. Water was also dripping and pooling inside the technical cabinet.

Official recommendation

Ensure the plumbing system in food areas is in good repair.

Item 33

Where it was found: Galley-Deck 10 - Mistral Hot Area Preparation Area

Official finding: Plastic food service gloves were secured to potable water lines to stop two leaks in the technical area below the countertop heating units. Water was also dripping and pooling inside the technical cabinet.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 24

Where it was found: Galley-Deck 5 - Beach House Potwashing Area

Official finding: The sanitizing solution in the three-compartment sink measured less than 50 mg/L (ppm). The sink was in active use with multiple pots, pans, and utensils washed in this ineffective sanitizing solution.

Official recommendation

Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).

Item 36

Where it was found: Galley-Deck 5 - Beach House Hot Preparation Line

Official finding: The light intensity at the utensil storage rack measured less than 220 lux.

Official recommendation

Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces. Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.

Item 08

Where it was found: Galley-Deck 3 - Tides Beverage Station

Official finding: The backflow prevention device for the counter-mounted coffee machine was in disrepair, with mineral accumulating blocking the atmospheric vents.

Official recommendation

Maintain backflow prevention devices in good repair.

Item 21

Where it was found: Galley-Deck 3 - Tides Warewashing Area

Official finding: The plate transportation trolley was heavily scored and chipped, creating difficult-to-clean surfaces.

Official recommendation

Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Item 33

Where it was found: Provisions-Deck 2 - Meat and Vegetable Walk-In Freezers

Official finding: A layer of frozen accumulation collected on the deckhead and on multiple boxes storing food products. Several boxes were heavily damaged, creating food protection deficiencies.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 19

Where it was found: Provisions-Deck 2 - Meat and Vegetable Walk-In Freezers

Official finding: A layer of frozen accumulation collected on the deckhead and on multiple boxes storing food products. Several boxes were heavily damaged, creating food protection deficiencies.

Official recommendation

Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination. Protect food from contamination that may result from a physical, chemical, biological origin.

Other inspection items (5 findings)

Item 29

Where it was found: Pantry-9 - Suite Ambassador

Official finding: Water delivered through the faucet of the automatic handwashing sink measured 125°F and the user could not adjust the temperature. Crew initiated corrective action.

Official recommendation

Ensure handwashing sinks are equipped to provide water at a temperature of at least 29.4°C (85°F) through a mixing valve or combination faucet. For handwashing sinks with electronic sensors and other types of handwashing sinks where users cannot make temperature adjustments, ensure the temperature after the mixing valve does not exceed 49°C (120°F).

Item 39

Where it was found: Pantry-8 - Aft

Official finding: One fruit fly flew inside the pantry.

Official recommendation

Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.

Item 33

Where it was found: Bar-Deck 5 - Beach House

Official finding: The juncture between the back bar bulkhead and the shelf storing open bottles of liquor met at a 90° angle and was not coved, creating a difficult-to-clean surface.

Official recommendation

Cove all bulkhead/deck, equipment/deck, cabinet/deck, counter/bulkhead/backsplash, and deck sink coaming/deck junctures in galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, scrapping stations, food storage rooms, food transportation corridors, equipment or utensil storage rooms, and toilet rooms intended for use by food employees.

Item 21

Where it was found: Bar-Deck 5 - Beach House

Official finding: Uninsulated refrigerator chilled water lines dripped water into the undercounter technical space below the counter-mounted coffee machine. Crew initiated corrective action.

Official recommendation

Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance. Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards. Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.

Item 27

Where it was found: Bar-Deck 5 - Beach House

Official finding: Liquid pooled beneath dripping refrigerator chilled water lines on the bottom of the undercounter technical space below the counter-mounted coffee machine. Crew initiated corrective action.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Swimming pools and whirlpools (6 findings)

Item 10

Where it was found: Housekeeping-Deck 7 - Suite # 755 Heated Jetted Tub

Official finding: The heated jetted tub on the balcony of suite # 755 was not disinfected and drained from 9 February until 14 February and from 26 February until 28 February. Crew identified that the cabin was vacant; however, the log did not document the cabin was vacant or any draining and disinfection. This heated jetted tub was disinfected and drained between occupancies. (New VSP 2025 Environmental Public Health Standard)

Official recommendation

Drain jetted tubs once per day and clean and disinfect them every 7 days or between occupancies, whatever is more frequent. Disinfect with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value. Implement one of the following procedures for heated jetted tubs: (1) Drain, clean, and disinfect heated jetted tubs daily. Install a safety sign at the tub entrance advising users that using heated jetted tubs without the use of automated halogen and pH control may increase the risk of respiratory infections.

Item 10

Where it was found: Recreational Water Facilities-Hair and Lint Strainer Cleaning and Disinfection

Official finding: Records showed that the hair and lint strainer and strainer housing for the deck 10 main swimming pool were disinfected on 18 March 2026, and more than seven days elapsed before the next disinfection on 30 March 2026.

Official recommendation

Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly.

Item 10

Where it was found: Recreational Water Facilities-Deck 10 - Main Swimming Pool

Official finding: The shepherd’s hook was affixed to the starboard railing behind two lounge chairs and was not in a prominent or readily accessible location during an emergency.

Official recommendation

Provide a rescue or shepherd’s hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3.3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency.

Item 33

Where it was found: Bar-Deck 10 - Pool

Official finding: The juncture between the back bar bulkhead and the shelf storing open bottles of liquor met at a 90° angle and was not coved, creating a difficult-to-clean surface.

Official recommendation

Cove all bulkhead/deck, equipment/deck, cabinet/deck, counter/bulkhead/backsplash, and deck sink coaming/deck junctures in galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, scrapping stations, food storage rooms, food transportation corridors, equipment or utensil storage rooms, and toilet rooms intended for use by food employees.

Item 19

Where it was found: Bar-Deck 10 - Pool

Official finding: Open liquor bottles for bar service were stored overnight on exterior bar shelves without protection from external elements, allowing salt to accumulate on the bottles and bar shelves. A layer of salt accumulated on the external surfaces of liquor bottles and the shelf from overnight open-deck storage.

Official recommendation

Protect food from contamination that may result from a physical, chemical, biological origin. Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.

Item 27

Where it was found: Bar-Deck 10 - Pool

Official finding: A layer of salt accumulated on the bar shelf storing open bottles of liquor from overnight open-deck storage.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Gastrointestinal outbreak notices

No official CDC outbreak notice in the listings we collected is clearly matched to this ship. That is not a guarantee that no illness occurred; it only means none of the posted notices we have were matched here. See the outbreak list.

Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.