The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Galleys and dining rooms (10 findings)
Item 21
Where it was found: Galley-Deck 9 Pinnochios Pizzeria Front Counter
Official finding: The clamps on the sneeze guards were in disrepair and had silicone buildup wedged in between which made the area difficult to clean.
Official recommendation
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item 21
Where it was found: Galley-Deck 9 Duck and Diner
Official finding: The thermometer inside the undercounter refrigerator read 44°F, however temperatures were measured below 40°F with the inspectors thermometer.
Official recommendation
Ensure ambient air temperature-measuring devices are maintained in good repair and are accurate within the intended range of use.
Item 33
Where it was found: Galley-Deck 9 Cabanas
Official finding: The deckhead sprinkler system had a wide gap which exposed the plenum. This was repaired immediately.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 33
Where it was found: Galley-Deck 9 Cabanas
Official finding: Condensate collected on the deckhead above the hood-type potwash machine.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 37
Where it was found: Galley-Deck 9 Cabanas
Official finding: Condensate collected on the deckhead above the hood-type potwash machine.
Official recommendation
Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and to remove contaminants generated by equipment located under them.
Item 22
Where it was found: Galley-Deck 9 Cabanas Three Compartment Sink
Official finding: The temperature gauge on the hot water final rinse sanitizing compartment read 150°F. However, the water temperature measured 172°F with the inspector's thermometer.
Official recommendation
Provide a maximum registering temperature-measuring device to verify the temperature in the warewashing machines and the three-compartment sink.
Item 36
Where it was found: Galley-Deck 10 Palo
Official finding: The light intensity at the hot grills did not reach at least 220 lux because of two deckhead light bulbs in disrepair.
Official recommendation
Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces.
Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item 22
Where it was found: Galley-Deck 4 Animators
Official finding: The rack-type dish wash machine was out of order.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item 22
Where it was found: Galley-Deck 1
Official finding: The rack-type dishwash machine was out of order.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item 19
Where it was found: Buffet-Deck 1 Officer's Mess
Official finding: The movable sneeze guard protecting pastries was incorrectly positioned and did not protect the food out for service.
Official recommendation
Protect food on display from contamination by using packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (39 inches).
Other inspection items (1 finding)
Item 36
Where it was found: Bar-Deck 9 Cove Cafe
Official finding: The light intensity at the handwashing station did not reach at least 110 lux during operations.
Official recommendation
Ensure the light intensity is at least 110 lux (10 foot-candles) at 750 millimeters (30 inches) above the deck in walk-in refrigerator units, dry storage areas, linen storage, waiter stations, scrapping stations, and handwashing stations in bars.
Swimming pools and whirlpools (1 finding)
Item 10
Where it was found: Recreational Water Facilities-Crew Pool
Official finding: The crew pool safety sign did not state 'no children in diapers or who are not toilet trained.'
Official recommendation
Provide safety signs for all RWFs. Ensure signs are in a prominent and unobstructed location for all users of the RWF. At a minimum, include the following words: (1) Do not use these facilities if you are experiencing diarrhea, vomiting, or fever. (2) No children in diapers or who are not toilet trained; (3) Shower before entering the facility; (4) Bather load #. For children’s RWF safety signs, include the exact wording ?TAKE CHILDREN ON FREQUENT BATHROOM BREAKS? or ?TAKE CHILDREN ON FREQUENT TOILET BREAKS.?
Gastrointestinal outbreak notices
These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.
Official outbreak notices collected for this ship
Swipe sideways to see every column.
Sailing dates
Causative agent
Case counts
Source
11/11/2002-11/21/2002
Norovirus
Passengers: Data not available. Crew: Data not available.