The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (2 findings)
Item 10
Where it was found: Potable Water-Heated Jetted Tub Draining, Cleaning, and Disinfection
Official finding: The heated jetted tubs are not currently drained, cleaned, nor disinfected daily. Additionally, no safety signs (or pictograms) were posted at the entrances to these facilities. Crew stated they are currently draining, cleaning, and disinfecting the heated jetted tubs between occupancies.
Official recommendation
Implement one of the following procedures for heated jetted tubs: (1) Drain, clean, and disinfect heated jetted tubs daily. Install a safety sign at the tub entrance advising users that using heated jetted tubs without the use of automated halogen and pH control may increase the risk of respiratory infections. (2) With an approved variance, drain heated jetted tubs every 3 days. Clean and disinfect tubs twice a week or between occupancies, whatever is more frequent. No signage is required.
Item 08
Where it was found: Potable Water-Deck # C - Compartment 11, Reverse Osmosis Unit # 3
Official finding: The dedicated technical water line providing filling to the technical tanks was stripped blue/gray/blue without any other identification. Crew initiated corrective action.
Official recommendation
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.
Stripe or paint these lines, including potable water supply lines in technical lockers, at 5-meters (16.4 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Galleys and dining rooms (19 findings)
Item 20
Where it was found: Buffet-Deck 11 - Cabanas
Official finding: A soda gun had a slotted fastener in the food splash zone.
Official recommendation
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch). Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item 33
Where it was found: Galley-Deck 12 - Palo
Official finding: Water was pooled on the deck in front of the grooved grill.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 33
Where it was found: Galley-Deck 12 - Palo - Pasta Cooking Station
Official finding: Water was pooled on the deck in this area.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 33
Where it was found: Galley-Deck 3 - Animator's Palate - Grill Section
Official finding: An open crack was around the ventilation system knob (#17928) in the deckhead.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item 19
Where it was found: Buffet-Deck 2 - Hot Item Station
Official finding: Metal pans of hot food items out for self-service on the buffet line were not positioned in a manner to prevent potential contamination. A metal container of fried chicken was positioned behind a long metal container of fried fish. During service, the sleeve of a customer's shirt draped over the top of the container of fried chicken. Crew initiated corrective action.
Official recommendation
Protect food from contamination that may result from a physical, chemical, biological origin. Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item 33
Where it was found: Buffet-Deck 2 - Mess Beverage Station
Official finding: A sharp, difficult-to-clean gap penetrated the bulkhead next to the deckhead-mounted light fixture in front of the counter-mounted juice dispenser.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 24
Where it was found: Buffet-Deck 2 - Aft Service Area
Official finding: The sanitizing solution's chlorine concentration inside the bucket in front of the deck-mounted ovens measured greater than 200 mg/L (PPM). Crew initiated corrective action.
Official recommendation
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item 29
Where it was found: Galley-Deck 2 - Hot Preparation Area
Official finding: The water temperature delivered through the faucet of the sensor-activated handwashing sink across from cold room D-02-2-002 measured 124°F with a calibrated thermometer. The user was unable to adjust the temperature. Crew initiated corrective action.
Official recommendation
Ensure handwashing sinks are equipped to provide water at a temperature of at least 29.4°C (85°F) through a mixing valve or combination faucet. For handwashing sinks with electronic sensors and other types of handwashing sinks where users cannot make temperature adjustments, ensure the temperature after the mixing valve does not exceed 49°C (120°F).
Item 36
Where it was found: Galley-Deck 2 - Store Room # FD-02-011
Official finding: The light intensity in the far right corner of the space used to store unpackaged drinking glasses measured less than 110 lux.
Official recommendation
Ensure the light intensity is at least 110 lux at 750 millimeters (30 inches) above the deck in walk-in refrigerator units, dry storage areas, linen storage, waiter stations, scrapping stations, and handwashing stations in bars.
Ensure the light intensity is at least 110 lux behind and around mounted equipment, including counter-mounted equipment.
Item 16
Where it was found: Galley-Deck 2 - Enchanted Garden Bakery
Official finding: The internal temperatures of two pieces of sponge cake stored inside reach-in refrigeration unit # 15660 measured 44°F and 43°F with a calibrated thermometer. The sponge cake was prepared on 21 June 2026. The ambient temperature inside the unit measured below 41°F. Crew initiated corrective action.
Official recommendation
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain TCS/PHF at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Maintain shell eggs that have not been treated to destroy all viable Salmonella spp. are maintained at 7°C (45°F) or less.
Item 29
Where it was found: Galley-Deck 2 - Enchanted Garden Potwashing Area
Official finding: The water temperature delivered through the faucet of the sensor-activated handwashing sink at the soiled end of the potwashing area measured 123°F with a calibrated thermometer. The user was unable to adjust the temperature. Crew initiated corrective action.
Official recommendation
Ensure handwashing sinks are equipped to provide water at a temperature of at least 29.4°C (85°F) through a mixing valve or combination faucet. For handwashing sinks with electronic sensors and other types of handwashing sinks where users cannot make temperature adjustments, ensure the temperature after the mixing valve does not exceed 49°C (120°F).
Item 22
Where it was found: Galley-Deck 2 - Enchanted Garden Warewashing Area
Official finding: Liquid steadily dripped from the bottom of the conveyor-type warewashing machine's auxiliary rinse compartment and pooled on the deck below. Crew initiated corrective action.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item 35
Where it was found: Galley-Deck 2 - Enchanted Garden Warewashing Area
Official finding: Liquid pooled on the deck underneath a steady drip from the bottom of the conveyor-type warewashing machine's auxiliary rinse compartment. Crew initiated corrective action.
Official recommendation
Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item 24
Where it was found: Galley-Deck 2 - Enchanted Garden Warewashing Area
Official finding: The water temperature inside the final rinse tank, located at the bottom of the compartment inside the conveyor-type warewashing machine, measured 206°F with a calibrated thermometer. Crew initiated corrective action.
Official recommendation
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines.
Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item 33
Where it was found: Galley-Deck 3 - Royal Court Forward Beverage Station
Official finding: The rubber deck mat in front of the forward entrance ice machine was in disrepair, with numerous difficult-to-clean rough surfaces. Half of the rubber mat was missing, with numerous long fragments of rubbers not attached to the mat. Crew initiated corrective action
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure mats are designed to be removable and easily cleanable.
Item 26
Where it was found: Galley-Deck 3 - Royal Court Portside Warewashing Area
Official finding: The recessed food-contact surfaces of three escargot serving dishes were soiled with brown food debris. Crew initiated corrective action.
Official recommendation
Ensure food-contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils.
Item 33
Where it was found: Galley-Deck 3 - Royal Court Hot Preparation Area
Official finding: The grout between the deck tiles and the metal landing under the flat-top grill was missing and chipped, with dust collecting in areas of recessed.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 35
Where it was found: Galley-Deck 3 - Royal Court Hot Preparation Area
Official finding: Liquid pooled on the deck underneath a steady drip from the technical compartment for the aft soup kettle.
Official recommendation
Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item 33
Where it was found: Galley-Deck 3 - Royal Court Hot Preparation Area
Official finding: Liquid steadily dripped from the technical compartment for the aft soup kettle and pooled on the deck below.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Housekeeping (1 finding)
Item 41
Where it was found: Housekeeping-Deck # 3 - Men's Passenger Toilet, Midship
Official finding: The right handwashing sink's soap dispenser was unable to dispense soap. Crew initiated corrective action.
Official recommendation
Provide passenger and crew public toilet facilities (not including those in food areas) with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands. (Pictograms are acceptable.)
Other inspection items (4 findings)
Item 39
Where it was found: Pantry-11 - Flo's Cafe
Official finding: One fruit fly was flying near the handwashing sink at the entrance.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 26
Where it was found: Pantry-Deck 11 - Frozone Treats - Ice Machine
Official finding: A light pink residue was along the length of the upper lip panel above the ice thickness device.
Official recommendation
Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils. Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item 29
Where it was found: Pantry-Deck 11 - Frozone Treats
Official finding: The water temperature measured 123°F at the handwashing sink next to the fire screen door.
Official recommendation
Ensure handwashing sinks are equipped to provide water at a temperature of at least 29.4°C (85°F) through a mixing valve or combination faucet. For handwashing sinks with electronic sensors and other types of handwashing sinks where users cannot make temperature adjustments, ensure the temperature after the mixing valve does not exceed 49°C (120°F).
Item 19
Where it was found: Bar-Deck 12 - Meridian - Aft
Official finding: A bottle of raspberry syrup in refrigerator #3 did not have an identification label.
Official recommendation
Ensure containers holding food or food ingredients removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
Pest and insect management (1 finding)
Item 39
Where it was found: Food Service General-Integrated Pest Management
Official finding: Pests were present in the following food service areas:
Deck 2: Crew buffet: One small fly was on the bulkhead above the hot buffet line.
Deck 2: Crew mess beverage station, One small fly was on the bulkhead to the left of the reach-in refrigerator.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Swimming pools and whirlpools (1 finding)
Item 10
Where it was found: Recreational Water Facilities-Whirlpools
Official finding: The design for the ship's whirlpools does not include a skim gutter or any other source for effective skimming. This includes the following whirlpools:
Deck 13
Concierge whirlpool
Deck 11
Rainforest villa forward
Deck 11
Rainforest villa aft
Deck 11
Senses Villa Starboard
Deck 12
Walt suite
Deck 12 fwd
Roy suite
Official recommendation
For RWFs with skim gutters, ensure the water level reaches at least the skim gutter or overflow level for a portion of the pool perimeter to remove floating debris and the top portion of the pool water for treatment.
Gastrointestinal outbreak notices
These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.
Official outbreak notices collected for this ship
Swipe sideways to see every column.
Sailing dates
Causative agent
Case counts
Source
4/30/1995-5/4/1995
Shigella sonnei
Passengers: Data not available. Crew: Data not available.